Type & specification
Type
|
Description
|
Range of application
|
CL-8506
|
Single-phase energy meter test bench
|
Standard energy meter testing
|
CL-8506B
|
Single-phase multi-function energy
meter test bench
|
Multi-function/Intelligent energy meter testing
|
CL-8506C
|
Calibration bench
|
Energy meter error calibration
|
CL-8506D
|
Single-phase din-rail energy meter
test bench
|
Din-rail energy meter testing
|
CL-8506E
|
Single-phase energy meter test bench
|
ICT energy meter testing
|
Functional advantage
Signal source
Ø 7 " color large LCD
Ø Feature rich physical keyboard
Ø Precise digital synthesis technology
Ø 2nd-31st harmonics and other special waveforms
output
Power
amplifier
Ø Precise digital synthesized technology and sine
PWM technology
Ø Large capacity
Ø High performance
Ø Low power consumption
Ø Automatic warning
Ø Voltage circuit Short circuit protection
Ø Current circuit open circuit protection
Error
processor
Ø Each station distributed networking
Ø Reliable pulse testing and precise error testing
treatment technology
Ø Support multi-path pulse signal input
Ø Voltage access protection
Communication
Ø Opportunity of serial server configuration,
implement parallel communication of muti-station, improve work efficiency
Ø RS485 /RS232 /Infrared / Carrier optional
Others
Ø Modular design, good universality of parts, easy
to disassemble and maintain
Ø One-button checking and control management
system, automatic finish as per the scheme
Ø Customized as per specific function
Technical parameters
Parameter Item
|
0.03
|
0.05
|
0.1
|
Reference standard energy meter
|
CL-9560H/0.02
|
CL-9560/0.05
|
CL-9560/0.1
|
Output phase shift
|
0~359.99°,resolution:0.01°
|
Waveform distortion
|
Both voltage and current<0.5%(relative liner load)
|
Power Stability(PF>=0.5)
|
<0.03%/120s
|
<0.05%/120s
|
<0.1%/120s
|
Output capacity
|
Voltage:200VA(6 stations )Current:250VA(120A);
|
Voltage:400VA(24 stations)
Current:900VA(120A)if add meters, Max. current: 2000VA
|
Output frequency
|
40~70Hz ,resolution:0.01Hz
|
Starting up current
output
|
Min:1mA(0.3mA optional),
accuracy:5%,
starting
power:accuracy 5%
|
Communication interface
|
Test bench:RS232
Meters:RS485/RS232/IR/carrier wave
|
Environment condition
|
Temperature:20℃±5℃;humidity:<85% R.H.
|
Power supply
|
220V AC ±15% ( 50/60±2 ) Hz
|
|
|
|
|
|
Function parameters
Function
|
CL-8506
|
CL-8506B
|
CL-8506C
|
CL-8506D
|
CL-8506E
|
Base error
|
●
|
●
|
●
|
●
|
●
|
Creep testing
|
●
|
●
|
●
|
●
|
●
|
Starting up testing
|
●
|
●
|
●
|
●
|
●
|
Standard deviation
|
●
|
●
|
●
|
●
|
●
|
Standard energy meter
|
●
|
●
|
●
|
●
|
●
|
Power source
|
●
|
●
|
●
|
●
|
●
|
Error processing system
|
●
|
●
|
●
|
●
|
●
|
Multi-path pulse input
|
○
|
●
|
○
|
○
|
●
|
Auto searching mark
|
○
|
○
|
○
|
○
|
○
|
Double circuit current
|
○
|
○
|
○
|
○
|
○
|
GPS clock synchronization
|
○
|
○
|
○
|
○
|
○
|
Collective turnover &
Optoelectronic sampling
|
○
|
○
|
○
|
○
|
○
|
Note:●─standard;○─optional
Dimensions(unit:mm)
Stations
|
Number
of
rack
|
Type
|
Dimension
L×W×H
|
|
6
|
1
|
Bench
|
1600×750×1600
|
Integration
|
24
|
1
|
|
2200×750×1920
|
Integration
|
12
|
1
|
|
1600×700×1600
|
Fission
|
48
|
2
|
|
2200×750×1920
|
Fission
|
|