Type
& specification
Type
|
Description
|
Range of application
|
CL-8606
|
Three-phase
energy meter test bench
|
Standard
energy meter testing
|
CL-8606B
|
Three -phase multi-function energy
meter test bench
|
Multi-function energy meter testing
|
CL-8606C
|
Calibration
bench
|
Energy
meter error calibration
|
CL-8606D
|
Three -phase din-rail energy meter
test bench
|
Din-rail energy meter testing
|
CL-8606E
|
Three-phase
energy meter test bench
|
ICT
energy meter testing
|
Functional
advantage
Signal source
Ø 7 "
color large LCD
Ø Feature
rich physical keyboard
Ø Precise
digital synthesis technology
Ø 2nd-31st
harmonics and other special waveforms output
Power amplifier
Ø Precise
digital synthesized technology and sine PWM technology
Ø Large
capacity
Ø High
performance
Ø Low
power consumption
Ø Automatic
warning
Ø Voltage
circuit Short circuit protection
Ø Current circuit
open circuit protection
Error processor
Ø Each
station distributed networking
Ø Reliable
pulse testing and precise error testing treatment technology
Ø Support
multi-path pulse signal input
Ø Voltage
access protection
Communication
Ø Opportunity
of serial server configuration, implement parallel communication of muti-station,
improve work efficiency
Ø RS485 /RS232
/Infrared / Carrier optional
Others
Ø Modular
design, good universality of parts, easy to disassemble and maintain
Ø One-button
checking and control management system, automatic finish as per the scheme
Ø Customized
as per specific function
Technical
parameters
Parameter
Item
|
0.03
|
0.05
|
0.1
|
Reference standard
energy
meter
|
CL-9660H/0.02
|
CL-9660/0.05
|
CL-9660/0.1
|
Output phase shift
|
0~359.99°,resolution:0.01°
|
Waveform distortion
|
Both
voltage and current<0.5%(relative
liner load)
|
Power Stability(PF>=0.5)
|
<0.03%/120s
|
<0.05%/120s
|
<0.1%/120s
|
Output capacity
(Each
Phase)
|
voltage:300VA(6
stations)
current:350VA(120A)
|
voltage:300VA(16
stations)
current:900VA(120A)
if add
meters, Max. current: 2000VA,Max.
voltage: 1200VA
|
Output frequency
|
40~70Hz ,resolution:0.01Hz
|
Starting up current
output
|
Min:1mA(0.3mA optional),
accuracy:5%,
starting
power:accuracy
5%
|
Communication interface
|
Test bench:RS232
Meters:RS485/RS232/IR/carrier
wave
|
Environment condition
|
Temperature:20℃±5℃;humidity:<85% R.H.
|
Power supply
|
220V AC ±15% 50/60 Hz
|
|
|
|
|
|
|
Function
parameters
Function
|
CL-8606
|
CL-8606B
|
CL-8606C
|
CL-8606D
|
CL-8606E
|
Base error
|
●
|
●
|
●
|
●
|
●
|
Creep testing
|
●
|
●
|
●
|
●
|
●
|
Starting up testing
|
●
|
●
|
●
|
●
|
●
|
Standard deviation
|
●
|
●
|
●
|
●
|
●
|
Standard energy meter
|
●
|
●
|
●
|
●
|
●
|
Power source
|
●
|
●
|
●
|
●
|
●
|
Error processing system
|
●
|
●
|
●
|
●
|
●
|
Multi-path pulse input
|
○
|
●
|
○
|
○
|
●
|
ICT
|
|
|
|
|
●
|
Auto searching mark
|
○
|
○
|
○
|
○
|
○
|
GPS clock
synchronization
|
○
|
○
|
○
|
○
|
○
|
Collective turnover &
optoelectronic
sampling
|
○
|
○
|
○
|
○
|
○
|
Note:●─standard;○─optional
Dimensions(unit:mm)
Stations
|
Number
of
rack
|
Type
|
Dimension
L×W×H
|
|
6
|
1
|
Bench
|
2000×800×1200
|
Integration
|
8
|
1
|
|
2000×800×1600
|
Integration
|
16
|
1
|
|
2200×800×1920
|
Integration
|
32
|
2
|
|
2200×800×1600
|
Fission
|
|
|
Cabinet
|
600×800×1920
|
|
|